Petroleum Science >2016, Issue 3: 584-591 DOI: https://doi.org/10.1007/s12182-016-0106-5
Fluidization characteristics of different sizes of quartz particlesin the fluidized bed Open Access
文章信息
作者:Zi-Jian Wang,Jun Tang and Chun-Xi Lu
作者单位:
State Key Laboratory of Heavy Oil Processing, China University of Petroleum (Beijing), Beijing 102249, China;State Key Laboratory of Heavy Oil Processing, China University of Petroleum (Beijing), Beijing 102249, China;State Key Laboratory of Heavy Oil Processing, China University of Petroleum (Beijing), Beijing 102249, China
投稿时间:2015-05-15
引用方式:Wang, ZJ., Tang, J. & Lu, CX. Pet. Sci. (2016) 13: 584. https://doi.org/10.1007/s12182-016-0106-5
文章摘要
Fluidization characteristics of quartz particles
with different sizes are experimentally investigated in a
fluidized bed with an inner diameter of 300 mm and height
of 8250 mm. Results show that the average solid holdup
increases with the increase in superficial gas velocity and
the decrease in initial solid holdup in the dense zone of the
fluidized bed. The average cross-sectional solid holdup
decreases with increasing bed height and superficial gas
velocity. The bed expansion coefficient increases with the
increase in superficial gas velocity and the decrease in solid
holdup. Correlations of average solid holdup, average
cross-sectional solid holdup and bed expansion coefficient
are also established and discussed. These correlations can
provide guidelines for better understanding of the fluidization
characteristics.
with different sizes are experimentally investigated in a
fluidized bed with an inner diameter of 300 mm and height
of 8250 mm. Results show that the average solid holdup
increases with the increase in superficial gas velocity and
the decrease in initial solid holdup in the dense zone of the
fluidized bed. The average cross-sectional solid holdup
decreases with increasing bed height and superficial gas
velocity. The bed expansion coefficient increases with the
increase in superficial gas velocity and the decrease in solid
holdup. Correlations of average solid holdup, average
cross-sectional solid holdup and bed expansion coefficient
are also established and discussed. These correlations can
provide guidelines for better understanding of the fluidization
characteristics.
关键词
-
Fluidization characteristic Solid holdup Axial average section solid holdup Bed expansioncoefficient